Catalog No. LM602006

qNTQX® V Universal Multiplex One Step RT-qPCR Probe Kit

Perform reverse transcription and multiplex probe-based qPCR in one tube. The kit supports up to four-plex RNA assays using heat-stable reverse transcriptase and hot-start Taq.

One-step RNA detection
Up to four-plex
Heat-stable reverse transcriptase
Probe-based detection
RUO

Product overview

qNTQX® V Universal Multiplex One Step RT-qPCR Probe Kit (LM602006). This kit combines reverse transcription of RNA and subsequent quantitative amplification in a single reaction tube. It contains 2× MP Buffer and an Enzyme Mix with heat-resistant V Reverse Transcriptase and HotStart Taq DNA Polymerase. The optimized buffer contains Mg²⁺ and dNTPs and supports up to four-plex reactions. Add assay-specific primers, fluorescent probes, RNA template and water.

One-tube RT-qPCR

Reverse transcription and amplification take place sequentially in the same reaction tube.

Up to four targets

The handbook describes support for up to four-plex assays with target-specific primers and probes.

Two-component reagent system

Supplied as 2× MP Buffer and Enzyme Mix for flexible reaction preparation.


LM602006 Overview Image

Specifications

ParameterValue
TargetRNA, converted to cDNA in the same tube
DetectionMultiplex probe-based RT-qPCR
MultiplexingUp to four-plex
Components2× MP Buffer and Enzyme Mix
Recommended reaction volume25–50 µL
25 µL setup12.5 µL buffer + 1 µL Enzyme Mix
Reverse transcription50°C for 10 min; 42°C also permitted by the handbook
Template input1–10 µL
Storage / shipping−25 to −15°C / ice packs
Shelf life18 months
Intended useResearch use only

Pack sizes & ordering

Catalog No.TestsBuffer / Enzyme Mix
LM602006ES011001.25 mL / 100 µL
LM602006ES025006.25 mL / 500 µL
LM602006ES031,00012.5 mL / 1 mL
LM602006ES0410,000125 mL / 10 mL

Pack quantities correspond to the recommended 25 µL reaction setup. Source: LM602006 handbook, pp. 2–3.

Performance & validation

The handbook describes multiplex RNA detection with up to four targets in a single-tube RT-qPCR workflow. Heat-stable reverse transcriptase synthesizes cDNA, followed by hot-start Taq amplification. Numerical sensitivity, linearity and amplification-efficiency results are not supplied. Source: LM602006 handbook, pp. 2–3.

Up to four-plex

The optimized buffer is designed to support multiplex primer amplification. Validate each panel.

Single-tube RNA workflow

Reverse transcription and qPCR share one tube, reducing transfers between steps.

Reference programme

50°C for 10 min; 95°C for 5 min; 45 cycles of 95°C for 15 s and 60°C for 30 s.

Product documents

Product FAQs

Can I start with RNA?

Yes. Reverse transcription is included in the same tube before qPCR.

How many targets are supported?

Up to four-plex according to the handbook. Validate primers, probes and channel compatibility.

What do I add?

Target-specific primers and probes, RNA template and nuclease-free water.

Is this a single premixed reagent?

No. The kit contains separate 2× MP Buffer and Enzyme Mix.

How should it be stored?

Store at −25 to −15°C for up to 18 months. Shipping uses ice packs.

Is this product for diagnostic use?

No. For scientific research use only, not diagnostic or clinical procedures.

Scroll to Top