Catalog No. LM602017

qNTQX® Universal Advanced Multiplex One-Step RT-qPCR Mix (UDG Plus)

A multiplex one-step RT-qPCR kit combining a 5× buffer, enzyme mix and optional GC-Enhancer for probe-based RNA analysis.

One-step RT-qPCR
Multiplex RNA analysis
dUTP/UDG
RUO

Product overview

qNTQX® Universal Advanced Multiplex One-Step RT-qPCR Mix (UDG Plus), catalog no. LM602017, combines reverse transcription and multiplex quantitative PCR in one reaction tube. The enzyme mix contains a thermostable reverse transcriptase, hot-start Taq DNA polymerase, RNase inhibitor and UDGase. The kit supplies a 5× buffer and GC-Enhancer and supports standard or fast cycling for research RNA analysis.

Single-tube RNA workflow

Reverse transcription and qPCR take place in the same tube, reducing handling between steps.

Multiplex assay support

The buffer supports multiplex amplification. Optional GC-Enhancer is provided for difficult high-GC targets.

Swab and carryover considerations

The handbook describes direct oral-swab RT-qPCR support and a dUTP/UDG carryover-control system.

Specifications

ParameterValue
Format5× Multiplex RT-qPCR Buffer, RT-qPCR Enzyme Mix and GC-Enhancer
Enzyme mixThermostable reverse transcriptase, hot-start Taq, RNase inhibitor and UDGase
Reaction setup25 µL: 5 µL buffer, 1 µL enzyme mix, 0–5 µL GC-Enhancer
RNA input volume1–5 µL per 25 µL reaction
Primer concentration0.16 µM each in the example; adjustable 0.1–1.0 µM
Probe concentration0.08 µM each in the example; adjustable 50–300 nM
Recommended reaction volumes25 or 50 µL
Storage and shelf life−25 to −15°C; 12 months from manufacture
Intended useResearch use only

Pack sizes & ordering

Catalog No.Nominal testsBuffer / enzyme / GC-Enhancer
LM602017100500 µL / 100 µL / 500 µL
LM6020171,0005 mL / 1 mL / 5 mL
LM60201710,00050 mL / 10 mL / 50 mL

Volumes are listed in the order 5× buffer / enzyme mix / GC-Enhancer. Test counts correspond to the 25 µL example reaction. Source: LM602017 handbook, pp. 2 and 4.

Performance & validation

The handbook describes multiplex RNA amplification, direct oral-swab RT-qPCR support and fast detection within ≤35 minutes. Quantitative limits of detection and swab-matrix acceptance criteria are not supplied. Validate the sample preparation, assay and instrument. Source: LM602017 handbook, pp. 2–5.

Fast programme

50°C for 2 min and 95°C for 30 s, then 40 cycles of 95°C for 5 s and 60°C for 15 s.

Optional GC-Enhancer

Intended mainly for >70% GC targets with substantial non-specific amplification; add only when needed.

Instrument-dependent timing

Confirm fast-cycling support and the minimum fluorescence-acquisition time on your instrument.

Product documents

Product FAQs

Is a separate reverse-transcription reaction required?

No. Reverse transcription and qPCR are performed in the same tube.

Must GC-Enhancer always be added?

No. Use 0–5 µL in the 25 µL example, mainly for difficult >70% GC targets. Add only when needed.

Can oral swabs be used directly?

The handbook supports this application, but sample preparation and assay performance require validation.

How should the kit be stored?

Store at −25 to −15°C. Shelf life is 12 months from manufacture.

Is this product for diagnostic use?

No. It is for research use only.