Catalog No. LM801003

SEQQX® OnePot Pro DNA Library Prep Kit

An enzymatic DNA library preparation kit for Illumina and MGI sequencing, combining fragmentation, end repair and dA-tailing in one tube for 1 ng–1 µg DNA input.

1 ng–1 µg DNA input
One-tube fragmentation module
Illumina and MGI
RUO

Product overview

SEQQX® OnePot Pro DNA Library Prep Kit, catalog no. LM801003, prepares sequencing libraries from genomic DNA, full-length cDNA and similar samples. Enzymatic fragmentation replaces sonication, while fragmentation, end repair and dA-tailing are combined in one tube. The kit includes ligation reagents and a high-fidelity amplification mix and works with platform-matched adapters and primers for Illumina® or MGI® sequencing.

Integrated fragmentation module

Combine DNA fragmentation, end repair and dA-tailing in one tube without a separate sonication step.

Flexible DNA input

The handbook specifies 1 ng–1 µg input and supports animal, plant and microbial genomic DNA as well as full-length cDNA.

Platform and format options

Use matching Illumina® or MGI® adapters and primers; select standard packs or a 96 T automation-ready plate format.

Specifications

ParameterValue
MethodEnzymatic DNA fragmentation and sequencing library preparation
Input amount1 ng–1 µg DNA
Sample typesAnimal, plant or microbial genomic DNA; full-length cDNA
PlatformsIllumina® and MGI® with matching adapters and primers
Integrated moduleFragmentation, end repair and dA-tailing in one tube
Fragmentation reaction60 µL; 10 µL each of Smearase® Buffer 4.0 and Enzyme 4.0
Standard incubation4°C for 1 min; 30°C for 10–40 min; 72°C for 20 min
Adapter ligation110 µL reaction; 20°C for 15 min; heated lid off
Amplification50 µL reaction with 2× Ultima HF Amplification Mix
Additional reagentsPlatform-matched adapters/primers and DNA clean-up beads
Library QCFluorescence or qPCR quantification; capillary electrophoresis for size
Storage and shelf life−25°C to −15°C; up to 12 months
Intended useResearch use only; not for diagnostic or clinical procedures

Pack sizes & ordering

Catalog No.Pack sizeFormat
LM801003ES018 TStandard kit
LM801003ES0224 TStandard kit
LM801003ES0396 TStandard kit
LM801003ES0496 TAutomation-ready plate format

One test (T) corresponds to one library-preparation reaction; specify the required pack size and standard or automation-ready plate format when ordering.

Performance & validation

Bioanalyzer analysis of 250 ng standard genomic DNA shows that adjusting fragmentation time and temperature shifts the insert-size distribution under the tested conditions.

Time-dependent fragmentation

At 30°C, reference insert sizes shift from approximately 700 bp at 10 min to 150–200 bp at 40 min.

Temperature-dependent control

At 35°C, reference insert sizes shift from approximately 500–600 bp at 10 min to 130 bp at 40 min.

Electropherogram evidence

Figures 2 and 3 show Bioanalyzer traces after 2.0× bead purification. Optimize time and temperature for the sample and desired insert size.


LM801003 Performance1 Fragmentation PrecisionLM801003 Performance2 Species Compatibility Comparison

Product documents

Product FAQs

Which DNA inputs are supported?

The handbook specifies 1 ng–1 µg of genomic DNA, full-length cDNA or similar samples, including animal, plant and microbial genomic DNA.

Does OnePot mean the entire workflow is a single step?

No. Fragmentation, end repair and dA-tailing share one tube. Adapter ligation, clean-up, amplification and final QC follow.

Are adapters and all primers included?

Adapters are not listed as kit components. Short adapters require the index primers from the matching adapter kit; long adapters require a separately ordered, platform-matched Primer Mix.

How is insert size adjusted?

Adjust fragmentation time and temperature. For high-quality genomic DNA, 30°C for 15 min is a starting point for approximately 300–500 bp inserts; optimize for your sample.

How should the kit be stored?

Store all components at −25°C to −15°C for up to 12 months. Research use only.

Scroll to Top